Actron AC Error Codes

Fugitsu AC is a popular air conditioning brand that has been providing reliable and efficient cooling solutions for households and businesses for several years. With its commitment to innovation and quality, Fugitsu has become a trusted name in the air conditioning industry, offering a wide range of air conditioning products to meet the needs of different customers.

Free Website Template by Free-Template.co

Below you can find the list of Error Codes for Fugitsu AC

Tags: #Fugitsu, #FugitsuAC, #FugitsuACErrorCodes

Error CodesMeaning
E0:00Coms error - indoor to remote
E1:00Coms error - indoor to outdoor
E2:00Return air thermistor open circuit
E3:00Return air thermistor short circuit
E4:00Indoor coil thermistor open
E5:00Indoor coil thermistor shorted
E6:00Outdoor coil thermistor open
E7:00 Outdoor coil thermistor shorted
EA:00Outdoor ambient thermistor open
Eb:00Outdoor ambient thermistor shorted
Ec:00Discharge pipe themistor open
Ed:00Discharge pipe thermistor shorted
EE:00High Pressure problem
EF:00Discharge pipe temp. Problem - too high = short of gas
OOID to RC Comms Fail
O1 ID to OD Comms Fail
O2ID Air Sensor Open
O3ID Air Sensor Close
O4ID Pipe Sensor Open
O5 ID Pipe Sensor Close
O6OD Pipe Sensor Fail
O8Power Source Connection Failure
O9Drain Problem Float switch operated
OAOD Air Sensor Fail
OCDischarge sensor Fail
OEOutdoor High Pressure Heatsink error
11OD PCB Fail
12ID Fan Fail
13OD Signal Abnormal ID signal error
14OD EEPROM Fail
15Compressor Temp Failure
16Pressure Switch Error
17IPM Error
18CT Error
19Active Filter Module Error
1ACompressor Failure
1BOD Fan Failure
1CInverter to PCB Comms Fail
1D2 Way Valve sensor Fail
1EExpansion Valve Error
1FConnection ID Unit Error
20Indoor manual switch abnormal
24Excessive high pressure protection on cooling
25PFC circuit error
26Indoor signal error
27Indoor signal error
28Indoor heat exchanger temperature error
29Outdoor heat exchanger temperature (middle) error
2APower supply frequency detection error
2BCompressor temperature error
2CFour-way valve abnormal
Red Light OperationGreen Light TimerCurrent Models
Off2 FlashesReverse Comms Fail at Startup
Off3 FlashesReverse Comms Fail In Use
Off4 FlashesForward Comms Fail at Startup
Off5 FlashesForward Comms Fail In Use
Off8 FlashesWired Remote Control Failure
2 Flashes2 FlashesIndoor Air Sensor Fail
2 Flashes3 FlashesIndoor Pipe Sensor Fail
2 Flashes4 FlashesIndoor heat exchanger sensor error
2 Flashes6 FlashesFloat switch operated
3 Flashes2 FlashesOD Disch Sensor Fail
3 Flashes3 FlashesOD Pipe Sensor Fail
3 Flashes4 FlashesOD Air Sensor Fail
3 Flashes7 FlashesHeatsink Sensor Error
3 Flashes8 FlashesCompressor Temp Sensor Fail
4 Flashes2 FlashesForced Auto Switch Welded
4 Flashes3 FlashesMain Relay Welded
4 Flashes4 FlashesPower Failure
4 Flashes 7 FlashesVDD Permament Stop Protection
4 Flashes8 FlashesReverse VDD Permament Stop
5 Flashes2 FlashesIPM Protection
5 Flashes3 FlashesCT Abnormal
5 Flashes5 FlashesCompressor Failure
5 Flashes6 FlashesOutdoor Fan Failure
6 Flashes2 FlashesID Fan Motor Locked
Flashes3 FlashesID Fan Motor Rotation Error
7 Flashes 2 FlashesHigh Discharge Temperature
7 Flashes 3 FlashesHigh Pressure
7 Flashes4 Flashes4-Way valve abnormal
7 Flashes 5 FlashesPressure Switch Fail
7 Flashes6 FlashesCompressor Temperature error
8 Flashes 2 FlashesActive Filter AFM Fail 1st Time
8 Flashes 3 FlashesActive Filter AFM Fail 2nd Time
8 Flashes4 FlashesPFC Circuit Error
BlinkingBlinkingPCB Failure