Goodman AC is a popular air conditioning brand that has been providing reliable and efficient cooling solutions for households and businesses for several years. With its commitment to innovation and quality, Goodman has become a trusted name in the air conditioning industry, offering a wide range of air conditioning products to meet the needs of different customers.

Free Website Template by Free-Template.co

Below you can find the list of Error Codes for Goodman AC

Tags: #Goodman, #GoodmanAC, #GoodmanACErrorCodes

Error CodesProblem
A2Shorted sensor./Open sensor./Sensor disconnected./Sensor out of range.
A3Shorted sensor./Open sensor./Sensor disconnected./Sensor out of range.
E5Short in low voltage wiring.
EECompressor relay contacts welded.
b0Indoor blower motor problem./Communications errorbetween indoor and outdoor unit.
b9Indoor blower motor problem./Blocked filters./Restrictive/ undersized ductwork./Indoor-outdoor unit miss match.
d0Air conditioner/heat pump is wired as part of a communicating system and integrated control module does not contain any shared data.
d1Air conditioner/heat pump is wired as part of a communicating system and integrated control module contains invalid shared data or network data is invalid for the integrated control module.
d2Air conditioner/heat pump is wired as part of a communicating system and outdoor unit requires airflow greater than indoor unit’s airflow capability./ Shared data is incompatible with the system or missing parameters.
d3Shared data sent to integrated control module does not match hardware configuration.
d4Shared data on memory card has been rejected.
01Low refrigerant charge./Restriction in liquid line./Indoor blower motor failure.Indoor thermostat set extremely low.
02Blocked condenser coil./Outdoor fan not running.
03Intermittent thermostat demand./Faulty compressor relay.
04Compressor bearings are seized./Failed compressor run capacitor./Faulty run capacitor wiring./Faulty compressor wiring./Low line voltage.
05Power is disconnected./Failed compressor protector./Compressor not properly wired to control.
06Compressor start winding is open./Failed compressor run capacitor./Faulty run capacitor wiring./Compressor not properly wired to control./Faulty compressor wiring.
07Compressor run winding is open./Compressor no properly wired to control./Faulty compressor wiring.
08Low line voltage./ High line voltage.
09Control detects secondary voltage less than 18 VAC./Transformer overloaded./Low line voltage.