Haier AC is a popular air conditioning brand that has been providing reliable and efficient cooling solutions for households and businesses for several years. With its commitment to innovation and quality, Haier has become a trusted name in the air conditioning industry, offering a wide range of air conditioning products to meet the needs of different customers.
Below you can find the list of Error Codes for Hisense AC
Tags: #Hisense, #HisenseAC, #HisenseACErrorCodes
Error Codes | Problem |
---|---|
0 | No trouble |
1 | Outdoor coil temperature sensor in trouble |
2 | Compressor temperature sensor in trouble |
3 | Voltage transformer in trouble |
4 | Current transformer in trouble |
5 | IPM module protection |
6 | Over and under-voltage control |
7 | Communication trouble |
8 | Current overload control |
9 | Maximum current control |
10 | Communication trouble (between outdoor unit and driver unit) |
11 | Outdoor EEPROM in trouble |
13 | Compressor exhaust temperature too high control |
14 | Outdoor ambient temperature sensor in trouble |
15 | Compressor housing temperature control |
16 | Anti-freeze or overload control |
18 | DC compressor fails to start |
19 | DC compressor out of step |
33 | Room temperature sensor in trouble |
34 | Indoor coil temperature sensor in trouble |
35 | Between wire remote controller and indoor unit communication trouble |
36 | Communication between the indoor and outdoor in trouble |
37 | Water overbrimmed the pump |
38 | Indoor EEPROM in trouble |
39 | Indoor fan motor operation abnormal |
40 | Grid protection alarm (cabinet type) |
41 | Detecting failures by zero-crossing |
F0 | Wire remote controller EEPROM failure. Change wire remote controller. |
F1 | Wire remote controller temperature sensor failure. Change wire remote controller. |
F2 | Wire remote controller clock IC failure. Change wire remote controller. |
F3 | Wire remote controller humidity sensor failure. Change wire remote controller. |
FE | Communication between main control board & Wiring remote controller Fault (display on wiring remote controller). |
ER | Communication between main control board &display board Fault. |