Kelvinator AC is a popular air conditioning brand that has been providing reliable and efficient cooling solutions for households and businesses for several years. With its commitment to innovation and quality, Kelvinator has become a trusted name in the air conditioning industry, offering a wide range of air conditioning products to meet the needs of different customers.
Below you can find the list of Error Codes for Kelvinator AC
Tags: #Kelvinator, #KelvinatorAC, #KelvinatorACErrorCodes
Error Codes | Problem |
---|---|
EE | Loading EEPROM Malfunction |
E2 | Anti-Freeze Protection |
E3 | Refrigeration System Blocked/Gas Leak |
E4 | Compressor High Temp Protection |
E5 | AC-Over Current Protection |
E6 | Communications Fault |
E8 | Anti-High Temperature Protection |
F1 | Sensor, Room Temperature (Indoor) |
F2 | Sensor, Tube Temperature (Indoor) |
F3 | Sensor, Ambient (Outdoor) |
F4 | Sensor, Coil (Outdoor) |
F5 | Sensor, Compressor Discharge (Outdoor) |
F6 | Anti-High Temperature Protection |
FH | Anti-Freeze Limit, Frequency Drop |
H1 | Defrosting. It is normal. The unit is in defrosting mode and heating will recommence soon. |
H3 | Compressor Overload Protection |
H5 | IPM Protection |
H6 | Fan Stall, Indoor Unit |
HC | PFC Protection |
P1 | Compressor Rated Frequency-Test State |
P2 | Compressor Maximum Frequency-Test State |
P3 | Compressor Medium Frequency-Test State |
PH | High Voltage Protection |
PL | Low Voltage Protection |
PO | Compressor Minimum Frequency-Test State |
LP | Indoor & Outdoor Units Don’t Match |
L3 | Outdoor DC Fan Motor Malfunction |
C5 | Jumper Cap Malfunction |
d1 | Compressor off |
d2 | The air conditioner continues to cool or heat during the demand response event,but the electrical energy consumed by the air conditioner in a half your period is not more than 50% of the total electrical energy that would be consumed if operating at the rated capacity in a half hour period. |
d3 | The air conditioner continues to cool or heat during the demand response event, but the electrical energy consumed by the air conditioner in a half your period is not more than 75% of the total electrical energy that would be consumed if operating at the rated capacity in a half hour period. |
Outdoor Error Codes | Meaning |
---|---|
E2 | Freeze Protection |
H5 | IPM protection |
E5 | Overcurrent protection |
EE | EEPROM reading and writing malfunction |
PL | Low voltage protection |
PH | High voltage protection |
HC | PFC overcurrent protection |
LP | Mismatching of models of indoor and outdoor units |
F3 | Malfunction of outdoor ambient temperature sensor |
F4 | Malfunction of outdoor pipe temperature sensor |
F5 | Malfunction of outdoor discharge temperature sensor |
E6 | Communication malfunction |
E3 | Low pressure protection(refrigerant leak) |
U7 | Abnormality of 4-way valve |
E8 | Over-load protection |
E4 | Discharge temperature protection |
H3 | Overload protection |
L9 | Over power protection |